First-Aid Kits for Circuit Boards
|
|
|
|
7.4.1 Soldering Surface Mount J Lead Components Point To Point Method
Outline
This procedure covers the general guidelines for soldering surface mount J lead components. There is basically only one style of J lead component. Whether leads are on two sides or four sides, or whether the component is large or small, the soldering principles are the same.
Minimum Skill Level - Intermediate
Recommended for technicians with skills in basic soldering and component rework, but may be inexperienced in general repair/rework procedures.
Conformance Level - High
This procedure most closely duplicates the physical characteristics of the original, and most probably complies with all the functional, environmental and serviceability factors.
| Acceptability References |
| IPC-A-610 12.0 |
Surface Mount Assemblies |
| Tools and Materials |
|
Cleaner
General purpose cleaner for removing contamination. |
|
Microscope
It is a challenge to undertake precision repair without a good microscope. |
|
Soldering Iron, Solder and Flux
A well maintained soldering iron is a must at every tech bench. |
|
Wipes
Nonabrasive, low-linting wipes for cleanup. |
|
| Images and Figures |
 |
| Surface Mount J Lead Component |
|
 |
| Figure 1: Place component and check alignment. |
|
 |
| Figure 2: Place the soldering iron tip at the junction between the pad and component lead. |
|
 |
| Figure 3:A - Dot indicates pin 1.B - Indicates pin 5.C - Indicates direction of pin count. |
|
Procedure
- Add liquid flux to the corner pads.
- Place the component in position and hold it steady. The leads must be aligned with the pads. On large components this is best done by aligning the leads on opposite corners. (See Figure 1).
- Place the soldering iron tip at the junction between the pad and component lead at one of the corners. Apply additional solder as needed. (See Figure 2).
- Remove the tip. Wait a moment for the solder to solidify before soldering the opposite corner.
- After the opposite corner is soldered, solder the remaining leads.
- Clean, if required and inspect.