| 9.4.1 BGA Component Reballing, Fixture Method |
Print |
Printed Board Type: R/F/C
Skill Level: Advanced
Conformance Level: High
Revision: A
Revision Date: 26 January 2006
OUTLINE This procedure covers reballing of BGA components.
| TOOLS AND MATERIALS |
Refer to Circuit Technology Center specific component reballing
instructions for machine operation, spacer construction and
screen ordering .
For plastic or tape (generally metal covered
components) the process will be to add flux paste first then apply solder
balls.
Standard Reballing Flux is: EFD, FluxPlus 6-411-A Paste
Flux. This may be changed upon customer specification.
Standard
Solder Paste is: EFD SolderPlus 63 RMA-A. This may be changed upon
customer specification. | PROCEDURE
NOTE BGA devices are
sensitive to the affects of moisture absorption. Proper baking according
to industry moisture senstive device (MSD) guidelines is critical to ensuring
re-balling and subsequent BGA rework success.
-
 |
| Ball Grid Array Rework Station |
|
Turn on the oven and preheat to 350° Fahrenheit (176° Celsius).
Allow approximately 20 - 30 minutes for temperature to settle between 338° to
356° F (170° to 180° C). Ensure the FR4 baking platform (.125) is out of the
oven. This platform will need to be at ambient temperature so that component
placement is simple and smooth preventing ball disruption. Place a
thermocouple at an appropriate location near the component in order to properly
monitor ball temperatures.
- At the Re-balling Machine turn on the machine vacuum. Align the ball
stencil. If there is slight misalignment between the flux / solder paste stencil
and the ball stencil, typically it is more important that the ball stencil be
precisely aligned than the flux stencil. Flux deposition does not require the
precision of the ball on the component pad. The stencils are basically held in
place and alignment is done by moving the component within its nest. In
the instance that flux deposition requires absolute precision utilize specified
CTC stencil adapters (in-house machined) to ensure fixture height, depth and
width exactly conform to reballed part dimensions .
NOTE The ball stencil may be a combination
of two or three stencils stacked on top of each other. Look through a microscope
and ensure the stencils are properly aligned. There are locating pins that are
placed to do this but the stencils may slip off the edge of the pins.
- Place Flux screen over component. Verify screen alignment under a
microscope. Screens are not held fully rigid at their base.
- Brush flux onto the component pads through the screen. It is important to
get flux on every single pad. When flux is not applied the pad will not hold the
solder ball when the balls are dropped into place. Additionally, a dry
pad, even if it holds a ball in place, will not properly wet to the solder ball
during reflow. On the other hand avoid applying too much flux as excess
flux on the component will potentially gum up the solder ball screen preventing
proper ball drop onto the component. Once flux is brushed over the screen holes
use a stainless steel squeegee to press the flux into the apertures.
- Lift the screen. Inspect under a microscope. If any pad is missing flux,
apply a small amount with an Xacto blade tip.
- Apply solder balls over the hole locations.
NOTE The more balls that are accurately placed
initially the quicker the process and the fewer balls will roll free on the
screen. An excess amount of free balls placed on the screen may make lifting the
screen clear and removing excess balls difficult. Excess balls may spill onto
component.
- Once the balls are on the screen, the ones that are not in holes may be
placed with a shortened acid brush (cut down to about .25" length). Lift the
screen once all balls are in place. Excess balls may be collected by lifting the
screen and tapping the balls into an ESD protective container.
NOTE Balls that stick with the screen must be
replaced on the component surface. Make extra balls available on a convenient
surface. These balls may be placed on the component pads by touching a minute
amount of flux paste flux to the tip of an Xacto blade, lifting a replacement
ball (using the surface tension of the flux) and laying it in place on the
component pad.
- Once all balls are in place the component may be gently propped up with an
Xacto blade then the spatula placed under the component to lift. Gently slide
the spatula under the component and keep the component angle as low as possible
while lifting. Once lifted, place the component on the FR4 baking platform.
- Turn the oven off momentarily (Preventing the distraction caused by the heat
and air flow of the convection oven). Open the oven door and gently place the
Baking platform in the oven. Close the oven door. Inspect the component balls
with a microscope through the glass oven door. If any balls have been dislodged
they will have to be put back in place. The balls do not have to be perfectly
centered on the pads as surface tension will center them during reflow.
- Turn the oven on at 500°F (260°C). On restart the oven airwill be at about
240°F (115°C). It will ramp up to reflow temperature in about 2-3 minutes. The
part itself will heat up relatively slowly and will take about 5-7 minutes to
reflow. The balls will not reflow until the oven temperature reaches about 448o
degrees Fahrenheit (231° Celsius). Testing has demonstrated that using this
procedure the component temperature will not exceed 205°C (401°F).
NOTE The re-starting temperture of
the oven can vary widely due to different times taken to place components.
Testing on component temperatures indicates that the most aggressive placement
of the components (placing in the oven when the oven temperature is 240°F
(115°C) ) results in a slightly greater than 1oC per second rise in temperature
for the first minute. After the first minute the ramp rate slows considerably.
NOTE The BGA component
may also be reflowed using an appropriate reflow cycle at a BGA rework
machine or run through a bench top reflow
oven.
- Once the component temperature reaches about 5 degrees short of 361°F
(183°C) observe the balls closely. When reflow begins clock 30 seconds. After 30
seconds turn off the oven to begin temperature down ramp. Very gently open oven
door by two or three inches to facilitate an appropriate cool down ramp. Place
the small deionizing fan on high about two inches from the opening to promote
even cooldown of the oven chamber.
NOTE The cooldown temperature ramp of the air will
occur relatively rapidly (still less than 2°C per second in the first
minute). At 130°C the components may be taken from the oven to ambient air
to cool.
- Using gloves remove the package from the oven at about 266° F (130°
Celsius). Allow components to cool in ambient temperature for three minutes to
ensure package thermal stability prior to component movement.
EVALUATION
- The component balls should be perfectly aligned and lustrous in appearance.
If this is not the case, stop the project and consult with project engineer.
- Inspect the body of the component for deformation. Also inspect for
dings and nicks in the substrate, potting compound or die cover. Notify
engineering of any defects.
- Inspect the underside of the BGA for cleanliness, flux residue and debris
left over from reballing process. If the BGAs are not perfectly clean,
inform engineering for process corrections.
This document has been
prepared by Circuit Technology Center, Inc.. The purpose is to ensure
repeatable, high quality rework of BGA components, and to assure conformity to
the highest industry standards and specifications.
NOTE This document covers procedures and guidelines
specific to BGA component rework conducted by the staff at Circuit Technology
Center, Inc. Organizations using this information may need to make
modifications, or other changes, to accomodate their own particular needs.
|
|