CircuitMedic
45 Research Drive, Haverhill, MA 01832 USA
Article Page: http://www.circuitmedic.com/guides/8-3-1.shtml
Circuit Board Rework and Repair Guide
8.3.1 Component Removal, Surface Mount J Lead Components, Conduction Method
Printed Board Type: R/F/W/C
Skill Level: Advanced
Conformance Level: High
Revision: D
Revision Date: Jul 7, 2000
OUTLINE
 |
| Surface Mount J Lead Component |
|
This procedure covers one commonly used method for
removing surface mount J lead components.
NOTE The goal when removing any
component is to remove the component as quickly as possible
TOOLS & MATERIALS Caliper Cleaner Conduction
Removal Tool with Tips Flux, Liquid Microscope Oven Positioning
Table Rework Stand Soldering Iron with Tips Wipes
PREPARATION
 |
| Figure 1: Conduction tip shown with solder added to enhance removal operation. |
|
This
method uses tips that are designed to fit over the top of surface mount
components, and to reflow all the solder joints at once. The tip fits over the
component with just a slight amount of extra space for solder. Measure the
overall length and width of the component with a caliper to select the proper
size tip. Check the tip for proper fit prior to processing the part.
The tip should not fit the component so tightly that it will get lodged in
the tip, but the tip should not be so loose that it will not conduct heat to all
the leads simultaneously
Conduction tips come in several sizes to accommodate many of the different
styles and sizes of components, but the component must fit properly in the tool
cavity. Since these tips have a cavity, they require special cleaning and
tinning procedures.
NOTE Carefully inspect the tip to
ensure that all surfaces will properly contact the component leads.
- Remove any solder from inside the tip cavity with a fiber tool.
CAUTION Do not use a wire brush for any
tip cleaning procedure. A wire brush can severely scratch a metal tip. Scratches
allow oxidation to form on the base metal of the tip and this will severely
decrease the useful life.
- Remove any oxidized solder by shocking the tip on a wet sponge. Remove
stubborn charred residue using an orange stick or polishing bar.
- Add solder to the properly prepared tip. Fill the cavity until there is a
fillet on the entire length of each side of the tip. (See Figure 1). Add enough
solder to help transfer the heat quickly but not so much that it will fall out
when the tip is turned upside down. The entire conducting surface of the tip
should be tinned with solder to promote proper heat transfer to the leads of the
component to be removed.
 |
| Figure 1: Conduction tip shown with solder added to enhance removal operation. |
|
The solder provides surface tension to lift the component off the
pads after reflow. Since the tip has more metal surface area than the pads on
the circuit board, the solder will be drawn toward the metal tip and so will the
component.
NOTE Determine the direction the
part is to be swept off the circuit board surface. Densely packed circuit board
assemblies often leave only one direction for the rework tool to follow when
sweeping the part off the surface.
PROCEDURE
Preview a Video Clip
Flux Application
(400KB) Alternate Bridge Fill
(500KB)
Alternate Solder Wrap
(900KB)
-
 |
| Figure:3;A - Dot indicates pin 1;B - Indicates pin 5;C - Indicates direction of pin count. |
|
Apply a small amount of liquid flux to all leads of the
component.
- Place the tip directly over the top of the component. The extra solder on
the tip will melt all the solder joints. When the solder has melted slide the
component out and up. (See Figure 2).
It's difficult to know precisely how long to dwell prior to safely removing
the part. This is complicated by the fact that when removing a bank of
components, parts subsequent to the first come off much faster. Obviously, the
smaller the part the quicker it reflows. Small SMT components may reflow in a
few seconds and large SMT components may take more than a minute.
On the smaller components you can usually see solder reflow and can then
sweep the component off and up. On larger components it is wise to attempt to
view reflow but often this is not possible. If you cannot clearly see reflow
very lightly rock the component to test for movement. If the component moves
freely then it is ready to be swept off the pads and lifted up.
Once the component is removed from the circuit board it can be removed from
the tip by the shocking sponge or with a dull blunt instrument applying downward
pressure on the component.
- Clean the area.
CircuitMedic
45 Research Drive, Haverhill, MA 01832 USA
Phone: 978-374-5000 · Fax: 978-372-5700
Website: www.circuitmedic.com
© 2006 Circuit Technology Center and CircuitMedic. All rights reserved.
CircuitMedic is a Circuit Technology Center brand.
|