Safety Data Sheet 115-3841/115-3844
CircuitMedic, 22 Parkridge Road, Haverhill, MA 01835 USA
Phone: 978-373-1600 | Website: http://www.circuitmedic.com
CircuitMedic disclaims all liability associated with the use of this information.
Revision Date: Jun 4, 2016
Page 1 of 5 Pages
Section 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
Product Name: Plating Solution, Electroclean
Product Number: 1 oz: 115-3841, 4 oz: 115-3844
Distributor: CircuitMedic
22 Parkridge Road, Haverhill, MA 01835 USA
PHONE: 978-373-1600, FAX: 978-372-5700
Emergency Response: For Chemical Emergency Spill, Leak, Fire, Exposure, or Accident
Call CHEMTREC Day or Night
Within USA and Canada: 1-800-424-9300 CCN4877
Outside USA and Canada: +1 703-527-3887 (collect calls accepted)
Electroclean Plating Solution

Section 2. HAZARD IDENTIFICATION
Classifications: Classification according to Regulation(EC)No1272/2008
Classifications applicable to the OSHA GHS Hazard Communication Standard (29CFR1910.1200)
Emergency Overview:
Potential Health Effects:
Inhalation: Irritating to the eyes, nose, throat and lungs. May cause sneezing, watering of eyes, nasal discharge and coughing.
Eyes: Corrosive to the eyes and may cause severe eye damage.
Skin: Causes skin irritation. May cause skin burns.
Ingestion: May cause severe and permanent damage to mouth, throat and stomach.
Section 3. COMPOSITION, INFORMATION OR INGREDIENTS
Chemical Name RTECS # C.A.S. Number Weight % OSHA PEL ACGIH TLV ACGIH Ceiling NIOSH REL NIOSH IDLH
Sodium Hydroxide WB4900000 1310-73-2 1-5 2mg/M3 N/A 2mg/M3 2mg/M3 10mg/M3
Water ZC0110000 7732-18-5 95-99 N/A N/A N/A N/A N/A

OSHA HAZARDOUS COMPONENTS (29 CFR 1910.1200): Exposure Limits 8 Hours TWA (PPM)
Section 4. FIRST AID MEASURES
Inhalation: Remove to fresh air. Lay victim down, legs raised. Loosen tight clothing, cover with a blanket, If not breathing, give artificial respiration. If breating is difficult, give oxygen.
Eye Contact: Hold eyelids apart and flush with plenty of water for at least 15 minutes.
Skin Contact: Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Thoroughly decontaminate (or discard) clothing and shoes.
Ingestion: DO NOT induce vomiting, unless advised by EMS. Give victim large quantities of water or milk with 1-2 fresh eggs. Give a glass of 1/3 vinegar with 2/3 water. Never give anything by mouth to an unconscious person.
Safety Data Sheet 115-3841/115-3844
CircuitMedic, 22 Parkridge Road, Haverhill, MA 01835 USA
Phone: 978-373-1600 | Website: http://www.circuitmedic.com
CircuitMedic disclaims all liability associated with the use of this information.
Revision Date: Jun 4, 2016
Page 2 of 5 Pages
Section 5. FIRE-FIGHTING MEASURES
Flash Point & Method: 230°F (C.O.C.).
Flammable Limits: LEL: 1.1 UEL: 6.0
Autoignition Temperature: N/A
General Hazard: Containers can build up pressure and burst if exposed to heat (fire). Water runoff can cause environmental damage. Dike area for later disposal.
Fire Fighting Instructions: NIOSH/MSHA approved positive-pressure self-contained breathing apparatus. Structural fire fighters' protective clothing may not provide adequate protection.
Hazardous Combustion Prod. N/A
Flammable Properties: Material will not burn.
Extinguishing Media: All.
Section 6. ACCIDENTAL RELEASE MEASURES
Land Spill: Do not touch or walk through spilled material. Isolate hazard area and keep people away. Notify your facility emergency coordinator. Eliminate all sources of ignition. Provide maximum ventilation. Do not release into soil, sewers or natural bodies of water. Wear proper personal protective equipment (PPE). Carefully mop up or vacuum spill and triple rinse with water into suitable plastic container. Release of a reportable quantity (RQ) require notification of proper authorities. Dispose of according to local, state, and federal regulations.
Neutralizing Agent: Dilute Hydrochloric Acid (6M)
Section 7. HANDLING AND STORAGE
Storage Temperature: 60-90 degrees F
Storage Pressure: Atmospheric
Shelf Life: Unlimited when properly stored away from light in room temperature (60 C / 140F).
General: Use "buddy system" when working with chemicals. Do not get in eyes, on skin or on clothing. Do not breathe vapor, mist of gas. Use with adequate ventilation. Wash thoroughly after handling. Triple rinse container clean before discarding. Put nothing else in this container. Keep container tightly closed in upright position. Store at 60-90 degrees F away from incompatible materials and physical hazards. Do not remove or deface container labels.
Section 8. EXPOSURE CONTROLS AND PERSONAL PROTECTION
Engineering Controls: Local Exhaust ventilation is required. See section 2 for component exposure guidelines.
Personal Protection:
Respirator: If engineering controls are not feasible, the respiratory protection program must comply with OSHA's 29 CFR 1910.34, 30 CFR 11 and ANSI Z88.2 requirements.
Hand Protection: Protective Gloves Recommended (Nitrile, Neoprene, Vinyl, Latex).
Eye Protection: Use one of the following: Face Shield and Safety Glasses with Side Shields or Chemical Goggles (splash-proof).
Other Recommended: Use one of the following: Eye Bath, Safety Shower, Washing Station Nearby, Impervious Boots, Apron, Appropriate Protective Clothing.
Note 1: In accordance with good industrial hygiene, wash hands with soap and water after working with material.
Safety Data Sheet 115-3841/115-3844
CircuitMedic, 22 Parkridge Road, Haverhill, MA 01835 USA
Phone: 978-373-1600 | Website: http://www.circuitmedic.com
CircuitMedic disclaims all liability associated with the use of this information.
Revision Date: Jun 4, 2016
Page 3 of 5 Pages/b>
Section 9. PHYSICAL AND CHEMICAL PROPERTIES
Density: 1.044-1.054g/ml
pH: 12-14
Boiling Point: >100 degrees C, >212 degrees F
Freezing Point: <0 degress C, <32 degrees F
Vapor Density (Air = 1): N/A
% Volatile By Weight: N/A
% Solids: N/A
Evaporation Rate (Butyl Acetate = 1: <1
Solubility in Water: Complete
Viscosity: N/A
Molecular Weight: N/A
Physical State: Liquid
Molecular Weight: N/A
Appearance: Colorless liquid
Vapor Pressure(mmHg): N/A
Section 10. STABILITY AND REACTIVITY
General: Stable under normal ambient conditions
Incompatible materials and Conditions to Avoid: Avoid contact with amphoteric metals, strong acids, anhydrides and aldehydes.
Hazardous Decomposition or Byproducts: NA2O (Sodium oxide)
Hazardous Polmerization: Will not occur.
Section 11. TOXICOLOGICAL INFORMATION
Results of Component Toxicity Test Performed: Information not available.
Human Experience: Information not available.
Section 12. ECOLOGICAL INFORMATION
Further Information: Information not available.
Section 13. DISPOSAL CONSIDERATIONS
RCRA 40 CFR 261 Classification: Federal, State, and Local laws governing disposal of materials can differ. Ensure proper disposal compliance with proper authorities before disposal.
Safety Data Sheet 115-3841/115-3844
CircuitMedic, 22 Parkridge Road, Haverhill, MA 01835 USA
Phone: 978-373-1600 | Website: http://www.circuitmedic.com
CircuitMedic disclaims all liability associated with the use of this information.
Revision Date: Jun 4, 2016
Page 4 of 5 Pages
Section 14. TRANSPORT INFORMATION
This product is always shipped in very small quantities, less than 1 liter. Limited quantity exceptions are applicable for this product if requirements in 49 CFR 173.154 (b), are met. Under these exceptions, inner packaging must not be over 1.0 liters (0.3 gallon), net capacity for liquids, packed in strong outer packaging. Each package must not exceed 30 kg (66 lb) gross weight. In addition, shipments of these limited quantities are not subject to Subpart F (Placarding) of Part 172. Packages must comply with Subpart B of Part 172.

DOT, IATA, ICAO, and IMO Description:
Basic Description: Electrocleaning Solution
Proper Shipping Name: Sodium Hydroxide Solution
Hazard Class: 8
Packaging Group: II
UN Number: UN 1824
Label Requirements: 8 - Corrosive
Max. Shippable Qty.: 1 liter by Air, no Ground limitations
Packaging: Meets Performance Oriented Packaging Requirements
Reportable Quantity (RQ): N/A
1996 NAERG Guide#: 154
Limitations: N/A
Do not transfer to unmarked containers. Non-Regulated under D.O.T.
Section 15. REGULATORY INFORMATION
United States Federal Regulations:
MSDS complies with OSHA's Hazard Communication Rule, 29 CFR 1910.1200.
CERCLA/SUPERFUND,40 CFR 117, 302: None of the chemicals are Superfund hazards
SARA SUPERFUND AND REAUTHORIZATION ACT OF 1986 TITLE III Sections 302, 311, 312 and 313: Section 302 Extremely hazardous substances (40 CFR 355): None of the chemicals are Section 302 hazards.
Section 311/312 - Material Safety Data Sheet Requirements (40 CFR 370): By our hazard evaluation, this product is non-hazardous.
TOXIC SUBSTANCE CONTROL ACT (TSCA): All substances are TSCA Listed.
Section 311/312 - Material Safety Data Sheet Requirements (40 CFR 370): By our hazard evaluation, this product is non-hazardous.
TOXIC SUBSTANCE CONTROL ACT (TSCA): All substances are TSCA Listed.


International Regulations:
Canada Whims: NA
Europe EINECS Numbers: NA
Canadian Substance Inventory: One or more of the components of this product do not appear in the Canadian Substance Inventory.
Safety Data Sheet 115-3841/115-3844
CircuitMedic, 22 Parkridge Road, Haverhill, MA 01835 USA
Phone: 978-373-1600 | Website: http://www.circuitmedic.com
CircuitMedic disclaims all liability associated with the use of this information.
Revision Date: Jun 4, 2016
Page 5 of 5 Pages
Section 16. OTHER INFORMATION
Label Information:
European risk and Safety Phrases: N/A
European Symbols Needed: N/A
Canadian WHIMS Symbols: N/A
NFPA Hazard Rating: (1) Flammability (1) Health (0) Reactivity
Abbreviations Used in this Document: NE - Not Established, NA - Not Applicable/Not Available, NIF - No Information Found
References: Code of Federal Regulations (CFR)
The Sigma-Aldrich Library of Regulatory and Safety Data
Chemical Guide and OSHA Hazard Communication Standard
Various Federal, State & Local Regulations
To the best of our knowledge, the information contained herein is accurate. However, neither Circuit Technology Center, Inc., nor any of its subsidiaries assumes any liability whatsoever for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards which exist.