Circuit Medic 22 Parkridge Road
Haverhill, MA 01835 USA
www.circuitmedic.com
CBLANKAS Circuit Frame, Blank

CBLANKAS Circuit Frame, Blank


Circuit Frame used to repair damaged conductors and patterns on printed circuit boards. They have a dry-film adhesive backing and bond in seconds using a bonding iron or bonding system, providing a strong, IPC-recommended PCB repair solution.

THIS ITEM IS MADE TO ORDER
  • The minimum order is 50 pieces.
  • This item is available with Bright Tin, Tin/Lead, or Nickel/Gold Plating.
  • If an alternate plating is desired, specify at the time of order.
  • For a potential cross-reference, see 525-2201-1.
Base Material Specifications
Overall Frame Size 2.25" x 1.50" (57 x 38 mm)
Base Material Rolled Annealed Copper Foil, UNS C11000 (Alloy C110), ASTM B152, IPC-4562A, 0.0014 in (0.036 mm) thick.
Plating .0001" (.0025 mm) Bright Tin (Lead Free), RoHS Compliant
Surface Treatments Top side plated. Bottom side treated to promote adhesion.
Shelf Life Shelf life of base material without adhesive application is unlimited.
RoHS and REACH CircuitMedic Circuit Frames contain less than 0.1% by weight any substance listed as a very high concern in Article 59 of REACH.

Adhesive Backing Specifications
Adhesive Backing Optional adhesive backing film is applied using a quick-bond process that retains B-staged adhesive properties.
Adhesive Material B-staged modified acrylic film adhesive .002" (.051 mm) thick.
Certification Adhesive backing is certified to IPC-4203/18: Adhesive Coated Dielectric Films for Use as Cover Sheets for Flexible Printed Circuitry and Flexible Adhesive Bonding Films.
Solder Resistance Passes IPC-TM-650, 2.4.13 Solder Float Resistance 10 seconds at 288°C (550°F).
Bonding Temperature 475°F ± 25°F (246°C ± 14°C)
Bonding Pressure 200 - 400 psi (14-28 kg/cm2)
Bonding Time 30 seconds
Peel Strength Minimum 8 lbs/inch (1.43 kg/cm) after cure to FR-4 material.
Outgassing The Bonding Film used on Circuit Frames consistently meet the criteria for NASA applications. Maximum 1.0% TML and a Maximum 0.10% CVCM. Samples have been submitted for testing to Goddard Space Flight Center and other facilities, and the results are; Data Reference: GSC 17366; %TML: 0.94%; %CVCM: 0.06%
Shelf Life One year minimum. Each Circuit Frame package is stamped with the expiration date. Adhesive material is sensitive to light and heat. Store in a dark or refrigerated environment to preserve the shelf life.
Classifications
Harmonize Code 7410.21.6000
Export Administration Regulations (EAR) EAR99
Export Control Classification Number (ECCN) Not Applicable